Trane and American Standard Furnace Codes by Series

Trane & American StandardTrane S9X1, S9X2, S9B1, S8X1, S8X2, S8V2 and S9V2-VS and American Standard A801X, A951X and A952V gas furnaces, from their current installation manuals, plus older Trane and American Standard furnaces fitted with three replacement-control kitsLast updated:

A current Trane or American Standard furnace shows a fault as an E-code, such as E2.1 or E04, on the small display of its control board; older furnaces flash a red LED a set number of times. The same code can read differently between series, so find your series first. Every meaning below is copied from the manufacturer's own installation manual, with document number and page.

Key facts

FactDetail
Series coveredTrane S9X1, S9X2, S9B1, S8X1, S8X2, S8V2 and S9V2-VS; American Standard A801X, A951X and A952V; older Trane and American Standard furnaces fitted with replacement-control kits 18109, 17399 and 20350
Where the meanings come fromInstallation, operation and maintenance manuals FNR-SVX002B-EN, FNR-SVX008A-EN, FNR-SVX003A-EN, FNR-SVX001C-EN, A801X-SVX001-1D-EN, FNR-SVX004B-EN and FNR-SVX005B-EN, and service installer's guides 18-CH92D1-1A-EN, 18-CH76D1-1A-EN and 18-CH111D1-1A-EN, all in Trane Technologies' public eLibrary
How current furnaces show a faultAn E-code on the "7 Segment LED" display of the integrated furnace control (IFC)
How older furnaces show a faultA count of red LED flashes; a slow or fast green flash is normal operation
Readings that are not faultsIdL (idle), Ht, Ht1, Ht2 (heating), CL1, CL2 (cooling), HP1, HP2 (heat pump), COF (continuous fan), dFt (defrost)
LockoutE2.1 and E2.2 end in a one-hour lockout; we found no homeowner reset procedure in these manuals
Last checkedOctober 29, 2026

How to find your series

The model number on your furnace starts with the series: Trane's manuals list their models in full on the cover, from S9X1 and S9X2 to S9V2B040U3VSBB, and American Standard's from A801X040AM3SDA/B to A952V120DU5SB. Match the start of your model number to a row below. If it matches none of them, this page does not cover your furnace.

Series as printedBrandManual (revision used here)How it shows a faultSection
S9X1, S9X2, S9B1TraneFNR-SVX002B-ENE-code on displayjump
S8X1, S8X2TraneFNR-SVX008A-ENE-code on displayjump
S8V2TraneFNR-SVX003A-ENE-code on displayjump
S9V2-VSTraneFNR-SVX001C-ENE-code on displayjump
A801XAmerican StandardA801X-SVX001-1D-ENE-code on displayjump
A951XAmerican StandardFNR-SVX004B-ENE-code on displayjump
A952VAmerican StandardFNR-SVX005B-ENE-code on displayjump
*DD, *DC (1990–1999), *UD2, *DD2, TUX, TDX, AUX, ADX with a replacement controlTrane or American Standard ("* May be "A" or "T"")18-CH92D1-1A-EN, 18-CH76D1-1A-EN, 18-CH111D1-1A-ENGreen and red LED flashesjump

The older kit guides are why this page covers both brands: each prints one diagnostic table for models whose leading letter "May be "A" or "T"", or, in 18-CH111D1-1A-EN, for a model list that mixes TUX and TDX with AUX and ADX. The current American Standard series have their own manuals, and their tables are given separately below rather than borrowed from the nearest Trane series.

How to read a Trane or American Standard code

On the current furnaces the code is on the integrated furnace control's seven-segment display, and it alternates with what the furnace is doing. Trane's wording (FNR-SVX002B-EN, p. 95): "If an error occurs, an E*.* will alternately flash with the system mode and airflow request." The same page explains that "The status will alternate between the system mode and the airflow request every 2 seconds,", and the error alternates with them.

The status codes that are not faults are listed on the same page: "IDL = Idle, no demand for cooling, heating, or fan", "HT1 = Demand for 1st stage gas heat", "HT2 = Demand for 2 nd gas heat", "COF = Demand for continuous fan" and "DFT = Demand for outdoor unit defrost, furnace running in gas heat mode". The S9V2-VS manual adds Lr1 and Lr2, "First Stage Gas Heat Learning Routine" and "Second Stage Gas Heat Learning Routine", and ArF, "Calculated Airflow (Followed by Airflow times 10)" (FNR-SVX001C-EN, Table 38, p. 82).

The control also keeps a fault history. Every current manual here describes a "Last 6 Faults" (L6F) menu reached with the board's Menu and Option keys, and says the history is cleared by holding "Option" for at least 5 seconds (FNR-SVX002B-EN, p. 99). The manuals open with the line "Only qualified personnel should install and service the equipment." (FNR-SVX002B-EN, p. 1)

Lockouts

E2.1 and E2.2 are lockouts. The S9X manual's troubleshooting chart defines the first one (FNR-SVX002B-EN, p. 102): "RETRY Lock Out = 3 unsuccessful tries for ignition within a single call for heat. Lockout period is for one hour." E2.2 is "Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)" in every table that has it.

The number of ignition tries before the lockout is not the same everywhere: 3 on the S9X1, S9X2, S9B1, S8X1, S8X2, A801X and A952V, 6 on the A951X, and 7 on the S8V2. We found no homeowner reset procedure in these manuals. A code that keeps coming back after the lockout ends is a job for a qualified servicer.

S9X1, S9X2 and S9B1 codes

The S9 condensing furnaces in single stage (S9X1, S9B1) and two stage (S9X2) share one manual and one table, Table 43 of FNR-SVX002B-EN. The second-stage codes are marked as not applying to the single-stage S9X1 and S9B1.

Trane S9X1, S9X2 and S9B1 error codes, verbatim, Table 43, FNR-SVX002B-EN, pp. 98–99
CodeTrane's alarm explanation (verbatim)Page
E01Loss of the IRQ or other internal failures (Internal IFC error)98
E2.1Retry Exceeded (Flame never sensed, one hour lockout after 3 times)98
E2.2Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)98
E2.31st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times98
E3.1Shorted Pressure Switch, 1st Stage98
E3.2Open Pressure Switch, 1st Stage98
E3.3Shorted Pressure Switch, 2nd Stage (Not applicable for S9X1/S9B1)98
E3.4Open Pressure Switch, 2nd Stage (Not applicable for S9X1/S9B1)98
E04Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)98
E05Flame detected, should not be present98
E6.1Voltage reversed polarity98
E6.2Bad grounding98
E6.3(1) Igniter relay fails (2) Igniter open98
E7.11st Gas valve (MVL) is energized when it should be off98
E08Flame current is low, but still strong enough to allow operation98
E09Open Inducer Limit Switch or Condensate Pressure Switch98
E11(1) 1st stage gas valve not energized when it should be (2) 1st stage gas valve relay stuck closed (3) 2nd stage gas valve relay stuck closed (Not applicable for S9X1/S9B1) (4) 2nd stage gas valve energized when it should not be (Not applicable for S9X1/S9B1) (5) 2nd stage gas valve not energized when it should be (Not applicable for S9X1/S9B1)98
E12Open fuse99
E14 / E18Refer troubleshooting flow chart99

S8X1 and S8X2 codes

The S8X1 (single stage) and S8X2 (two stage) induced-draft furnaces use the same list as the S9 furnaces, without E09 or E14/E18, in Table 34 of FNR-SVX008A-EN. This October 2026 manual supersedes S8XB-SVX001-1D-EN.

Trane S8X1 and S8X2 error codes, verbatim, Table 34, FNR-SVX008A-EN, pp. 60–61
CodeTrane's alarm explanation (verbatim)Page
E01Loss of the IRQ or other internal failures (Internal IFC error)60
E2.1Retry Exceeded (Flame never sensed, one hour lockout after 3 times)60
E2.2Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)60
E2.31st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times60
E3.1Shorted Pressure Switch, 1st Stage60
E3.2Open Pressure Switch, 1st Stage60
E3.3Shorted Pressure Switch, 2nd Stage (Not Applicable for S8X1)60
E3.4Open Pressure Switch, 2nd Stage (Not Applicable for S8X1)60
E04Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)60
E05Flame detected, should not be present60
E6.1Voltage reversed polarity60
E6.2Bad grounding60
E6.3(1) Igniter relay fails (2) Igniter open61
E7.11st stage gas valve (MVL) is energized when it should be off61
E08Flame current is low, but still strong enough to allow operation61
E11(1) 1st stage gas valve not energized when it should be (2) 1st stage gas valve relay stuck closed (3) 2nd stage gas valve relay stuck closed (Not Applicable for S8X1) (4) 2nd stage gas valve energized when it should not be (Not Applicable for S8X1) (5) 2nd stage gas valve not energized when it should be (Not Applicable for S8X1)61
E12Open fuse61

S8V2 codes

The S8V2 is a two-stage induced-draft furnace with a variable-speed motor, built for a "Link Communicating or 24 Volt" system, and its control has the longest list: the open limit splits into three codes (E4.0, E4.1, E4.2), and E13 to E28 cover the blower, the configuration file and the air sensors. Table 37 of FNR-SVX003A-EN, which supersedes S8V2-SVX001B-EN.

Trane S8V2 error codes, verbatim, Table 37, FNR-SVX003A-EN, pp. 59–60
CodeTrane's alarm explanation (verbatim)Page
E01Loss of the IRQ or other internal IFC failures59
E2.1Retries exceeded (Flame never sensed, one hour lockout after 7 times)59
E2.2Recycles exceeded (Flame sensed then lost, one hour lockout after 10 times)59
E2.31st stage gas valve not energized when it should be (10 times)59
E3.1Shorted pressure switch, 1st stage59
E3.2Open pressure switch, 1st stage59
E3.3Shorted pressure switch, 2nd stage59
E3.4Open pressure switch, 2nd stage59
E4.0Open high limit switch59
E4.1Open reverse air-flow limit switch59
E4.2Open roll-out limit switch59
E05Flame detected when it should not be present59
E6.1Voltage reversed polarity59
E6.2Bad grounding59
E6.3(1) Igniter open or igniter relay failure on IFC (2) Igniter relay failure on IFC59
E7.11st stage gas valve energized without request59
E7.2Redundant relay (HLO output) energized when it should not be59
E08Low flame sense. Current is low but strong enough for operation59
E11(1) 1st stage gas valve not energized when it should be (2) 2nd stage gas valve energized without request (3) 2nd stage gas valve not energized when it should be (4) Gas valve relay stuck closed59
E12Open fuse59
E13Blower HP or OEM ID do not match furnace59
E14Configuration file error60
E17Blower communication error60
E23Menu parameters not received by CCM60
E24Internal communication error between the ACM and CCM60
E25Orientation sensor out of bounds60
E261) Return static pressure transducer out of bounds 2) Return static pressure transducer configured but not connected60
E271) Return air thermistor out of bounds 2) Return air thermistor configured but not connected60
E281) Supply air thermistor out of bounds 2) Supply air thermistor configured but not connected60

S9V2-VS codes

The S9V2-VS is a two-stage condensing furnace with a variable-speed draft inducer. Its manual, FNR-SVX001C-EN, has no separate error-code table; the codes are printed in the legend of the S9V2-VS wiring diagram (Figure 3, p. 19, diagram D346055P01 Rev E). Note E06, where the other series split polarity and grounding into E6.1 and E6.2.

Trane S9V2-VS error codes, verbatim, wiring diagram legend, Figure 3, FNR-SVX001C-EN, p. 19
CodeTrane's description (verbatim)Page
E01Loss of the IRQ/other internal failures19
E2.1Retry exceeded (Failed to est flame)19
E2.2Recycles exceeded (loss of established flame) or 10X PS1 open19
E2.31st Stage Gas Valve not energized when it should be exceeded after 10 times19
E2.4Redundant Relay (HLO output) Not Energized when it should be exceeded after 10 times19
E3.1Shorted Pressure Switch, 1st Stage19
E3.2Open Pressure Switch, 1st Stage19
E3.3Shorted Pressure Switch, 2nd Stage19
E3.4Open Pressure Switch, 2nd Stage19
E04Open Thermal Limit, Rollout Switch, or Reverse Airflow Switch19
E05Flame detected, should not be present19
E06Voltage reversed polarity or Bad Grounding19
E6.3(1) Igniter relay fails, (2) Igniter open19
E7.11st stage gas valve (MVL) is energized when it should be off19
E7.2Redundant Relay (HLO output) Energized when it should NOT be19
E08Flame current is low, but still strong enough to allow operation.19
E09Open Inducer Limit Switch or Condensate Switch19
E10Inducer Motor no communication response, could be communication failure between two micro-controllers.19
E11(1) 2nd stage gas valve energized when it should NOT be (2) 2nd stage gas valve not energized when it should be (3) 1st stage gas valve not energized when it should be (4) Redundant relay (HLO output) not energized when it should be19
E12Open fuse19
E13Blower HP/OEM ID19
E14No PM and local copy bad19
E15Both of Unit Data File in PM and local Unit Data File are Corrupt19
E17Blower motor no communication response19
E18Blower communication failure on the control19

American Standard A801X codes

The A801X is American Standard's single-stage induced-draft furnace. Its manual, A801X-SVX001-1D-EN, prints an error-code list on p. 48. It matches the Trane S8X1 list code for code, including the second-stage E11 conditions marked "(Not Applicable for A801X)", but has no E3.3 or E3.4 row.

American Standard A801X error codes, verbatim, A801X-SVX001-1D-EN, p. 48
CodeAmerican Standard's alarm explanation (verbatim)Page
E01Loss of the IRQ or other internal failures (Internal IFC error)48
E2.1Retry Exceeded (Flame never sensed, one hour lockout after 3 times)48
E2.2Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)48
E2.31st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times48
E3.1Shorted Pressure Switch, 1st Stage48
E3.2Open Pressure Switch, 1st Stage48
E04Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)48
E05Flame detected, should not be present48
E6.1Voltage reversed polarity48
E6.2Bad grounding48
E6.3(1) Igniter relay fails (2) Igniter open48
E7.11st stage gas valve (MVL) is energized when it should be off48
E08Flame current is low, but still strong enough to allow operation48
E11(1) 1st stage gas valve not energized when it should be (2) 1st stage gas valve relay stuck closed (3) 2nd stage gas valve relay stuck closed (Not Applicable for A801X) (4) 2nd stage gas valve energized when it should not be (Not Applicable for A801X) (5) 2nd stage gas valve not energized when it should be (Not Applicable for A801X)48
E12Open fuse48

American Standard A951X codes

The A951X is a single-stage condensing furnace. Table 35 of FNR-SVX004B-EN is the shortest list here, with single-stage wording ("Shorted Pressure Switch", "Gas valve") and a different lockout count: E2.1 locks out "after 6 times".

American Standard A951X error codes, verbatim, Table 35, FNR-SVX004B-EN, p. 76
CodeAmerican Standard's alarm explanation (verbatim)Page
E01Loss of the IRQ or other internal failures (Internal IFC error)76
E2.1Retry Exceeded (Flame never sensed, one hour lockout after 6 times)76
E2.2Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)76
E2.3Gas Valve Not Energized When It Should Be exceeded after 10 times76
E3.1Shorted Pressure Switch76
E3.2Open Pressure Switch76
E04Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)76
E05Flame detected, should not be present76
E6.1Voltage reversed polarity76
E6.2Bad grounding76
E6.3(1) Igniter relay fails (2) Igniter open76
E7.1Gas valve (MVL) is energized when it should be off76
E08Flame current is low, but still strong enough to allow operation76
E09Open Inducer Limit Switch or Condensate Pressure Switch76
E11Gas valve not energized when it should be; Gas valve relay stuck closed76
E12Open fuse76

American Standard A952V codes

The A952V is a two-stage condensing variable-speed furnace. Its Table 40 in FNR-SVX005B-EN carries the same blower and memory codes as the Trane S9V2-VS (E10 to E18), with E10 worded differently and polarity and grounding split into E6.1 and E6.2.

American Standard A952V error codes, verbatim, Table 40, FNR-SVX005B-EN, p. 89
CodeAmerican Standard's alarm explanation (verbatim)Page
E01Loss of the IRQ or other internal failures (Internal IFC error)89
E2.1Retry Exceeded (Flame never sensed, one hour lockout after 3 times)89
E2.2Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)89
E2.31st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times89
E2.4Redundant Relay (HLO output) Not Energized when it should be exceeded after 10 times89
E3.1Shorted Pressure Switch, 1st Stage89
E3.2Open Pressure Switch, 1st Stage89
E3.3Shorted Pressure Switch, 2nd Stage89
E3.4Open Pressure Switch, 2nd Stage89
E04Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)89
E05Flame detected, should not be present89
E6.1Voltage reversed polarity89
E6.2Bad grounding89
E6.31. Igniter relay fails 2. Igniter open89
E7.11st stage gas valve (MVL) is energized when it should be off89
E7.2Redundant Relay (HLO output) Energized when it should Not be89
E08Flame current is low, but still strong enough to allow operation89
E09Open Inducer Limit Switch or Condensate Pressure Switch89
E10Communication error between variable speed inducer and blower motor microprocessor89
E111. 1st stage gas valve not energized when it should be 2. 1st stage gas valve relay stuck closed 3. 2nd stage gas valve relay stuck closed 4. 2nd stage gas valve energized when it should not be 5. 2nd stage gas valve not energized when it should be89
E12Open fuse89
E13Blower HP/OEM ID89
E14No PM and local copy bad89
E15Both of unit Data File in PM and local Unit Data File are corrupt89
E17Blower motor no communication response89
E18Blower communication failure on the control89

Older furnaces with a replacement control

Older furnaces fitted with the replacement controls below flash LEDs instead. We did not find their original installation manuals with a code table in Trane's public library, but Trane does publish the guides for the replacement integrated furnace controls (IFC) that service technicians fit to them, and each guide prints the diagnostic table of the control it installs. These are the codes of that replacement control: if your furnace still has its original board, the label on its blower door is the reference. The guides list the furnaces they fit on p. 1 (18-CH111D1-1A-EN on p. 2); 18-CH92D1-1A-EN and 18-CH76D1-1A-EN add the note "* May be "A" or "T"".

  • Kit 18109, 18-CH92D1-1A-EN: "*DD---C---A0 up to and including *DD---C---H5 (1990-1999)" and "*DC---C---A0 up to and including *DC---C---B5 (1990-1998)".
  • Kit 17399, 18-CH76D1-1A-EN: seven *UD2 models from *UD2B060ACV32A to *UD2D140ACV52A, and four *DD2 models from *DD2B060ACV32A to *DD2D120ACV52A.
  • Kit 20350, 18-CH111D1-1A-EN: TUX, TDX, AUX and ADX models such as TUX080R942W5, TDX2B060A9362AB, AUX100R948W6 and ADX120R960W6.
Trane and American Standard replacement-control LED codes, verbatim, Integrated Furnace Control Diagnostic Codes, 18-CH92D1-1A-EN and 18-CH111D1-1A-EN p. 2, with 18-CH76D1-1A-EN p. 2
Green LED flashRed LED flashERROR (LitePort™ DATA), kits 18109 and 20350 (verbatim)Kit 17399, where different (verbatim)
1NORMAL OPERATION - Flash every 20 secondssame
2SYSTEM LOCKOUT RETRIES OR RECYCLES EXCEEDEDsame
3PRESSURE SWITCH FAULTsame
4OPEN LIMIT SWITCHsame
5FLAME SENSED WHEN NO FLAME SHOULD BE PRESENTsame
6115 VOLT AC POWER REVERSED OR IMPROPER GROUND115 VOLT AC POWER REVERSED OR IGNITER FAULT
7GAS VALVE CIRCUIT ERRORsame
8LOW FLAME SENSE SIGNALsame
9IGNITER RELAY FAULTOPEN INDUCER LIMIT
10not listedCOMMUNICATION FAULT
Continuous Onnot listedINTERNAL CONTROL FAILURE
Slow FlashNORMAL, NO CALL FOR HEATsame
Fast FlashNORMAL, CALL FOR HEAT PRESENTsame
Continuous OnContinuous OnINTERNAL CONTROL FAILUREsame
Continuous OffContinuous OffFUSE OPENsame

Same code, different meaning

These are the places where Trane's and American Standard's own documents give one code different wording or a different meaning. Read your own series' table, not the nearest number.

CodeWhere it means one thingWhere it means another
E2.1S9X1/S9X2/S9B1, S8X1/S8X2, A801X, A952V: "one hour lockout after 3 times"A951X: "after 6 times"; S8V2: "after 7 times"; S9V2-VS: "Retry exceeded (Failed to est flame)", no count
E04Most series: "Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)"S8V2 has no E04; it splits the limit into E4.0 "Open high limit switch", E4.1 "Open reverse air-flow limit switch" and E4.2 "Open roll-out limit switch"
E06 / E6.1 / E6.2S9V2-VS: E06 "Voltage reversed polarity or Bad Grounding"Every other current series: E6.1 "Voltage reversed polarity" and E6.2 "Bad grounding"
E09S9X1/S9X2/S9B1, A951X, A952V: "Open Inducer Limit Switch or Condensate Pressure Switch"S9V2-VS: "…or Condensate Switch"; not in the S8X1/S8X2, S8V2 or A801X tables
E10S9V2-VS: "Inducer Motor no communication response, could be communication failure between two micro-controllers."A952V: "Communication error between variable speed inducer and blower motor microprocessor"
E13S8V2: "Blower HP or OEM ID do not match furnace"S9V2-VS, A952V: "Blower HP/OEM ID"
E14S8V2: "Configuration file error"S9V2-VS, A952V: "No PM and local copy bad"; S9X1/S9X2/S9B1: "E14 / E18 Refer troubleshooting flow chart"
E17S8V2: "Blower communication error"S9V2-VS, A952V: "Blower motor no communication response"
6 red flashesKits 18109 and 20350: "115 VOLT AC POWER REVERSED OR IMPROPER GROUND"Kit 17399: "115 VOLT AC POWER REVERSED OR IGNITER FAULT"
9 red flashesKits 18109 and 20350: "IGNITER RELAY FAULT"Kit 17399: "OPEN INDUCER LIMIT"

What an owner can do, and what the manuals leave to a servicer

These manuals are written for installers and service technicians. What they say that touches the homeowner is short, and most of it is a warning:

TaskThe manual's wording (verbatim)Who
Filters"Filters should be cleaned or replaced (with high velocity filters only), monthly and more frequently during high use times of the year such as midsummer or midwinter." (FNR-SVX002B-EN, p. 117)Not stated
Blower door"Verify the blower door is in place and not ajar. Dangerous fumes could escape an improperly secured door." (FNR-SVX002B-EN, p. 3)Anyone who opens it
Burner flame"accumulation of foreign material may cause a yellowing flame or delayed ignition. Either condition indicates that a service call is required." (FNR-SVX002B-EN, p. 117)Service call
Blower cleaning"Annual cleaning of the Blower wheel and housing is recommended for maximum air output, and this must be performed only by a qualified servicer or service agency." (FNR-SVX002B-EN, p. 117)Qualified servicer or service agency
Installation and service"Installation and service must be performed by a qualified installer, service agency, or the gas supplier." (FNR-SVX008A-EN, p. 3)Qualified installer, service agency or gas supplier

Everything an error code points at, from pressure switches and limits to igniters, gas valves and the control board, is servicer work. The codes are worth writing down for the technician, including the L6F fault history if the servicer reads it out.

Trane's gas and carbon monoxide wording

The furnace pages on this site carry the general guidance above. This is the manufacturer's own wording, from the safety pages of the current manuals.

Wording (verbatim)Source
"Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service agency, or the gas supplier."FNR-SVX008A-EN, p. 3
"Install a gas detector for leak warnings. The manufacturer does not test or endorse any specific brand or type of detector."FNR-SVX008A-EN, p. 3
"Never test for gas leaks with an open flame."FNR-SVX008A-EN, p. 3
"The U.S. Consumer Product Safety Commission recommends that users of gas-burning appliances install carbon monoxide detectors as well as fire and smoke detectors per the manufactures installation instructions to help alert dwelling occupants of the presence of fire, smoke or unsafe levels of carbon monoxide."FNR-SVX002B-EN, p. 54
"The installer must verify that at least one carbon monoxide alarm has been installed within the residential living space or home following the alarm manufacturer's instructions and applicable local codes before putting the appliance into operation."FNR-SVX002B-EN, p. 19
"Carbon Monoxide Poisoning! … Verify the blower door is in place and not ajar. Dangerous fumes could escape an improperly secured door."FNR-SVX002B-EN, p. 3

Trane and American Standard furnaces not covered yet

Trane's public library also holds 2020–2022 revisions of several of these manuals (18-CE12D1-1D-EN for the S9 single and two stage, 18-CE14D1-1A-EN and 18-CE16D1-1C-EN for the S8B1, S8X1 and S8X2, 18-CE03D1-1F-EN and 18-CE19D1-1B-EN for the S9V2) and the American Standard A951X installer's guide 88-A951X001-1D-EN. This page uses the newest revision of each series. The S8B1 appears in the 2020–2021 S8 manuals but not in the October 2026 one, so it is not in the S8X table above.

For older furnaces whose original control is still fitted, we found no original installation manual with a code table in the public library, so this page has no table for them beyond the replacement-control kits.

For other brands' schemes, see the Goodman, Rheem and Carrier furnace code hubs.

Frequently asked questions

What does E2.1 mean on a Trane furnace?

The furnace tried to light and never sensed a flame, then locked out for an hour. On the S9X1, S9X2, S9B1, S8X1 and S8X2 the table reads "Retry Exceeded (Flame never sensed, one hour lockout after 3 times)"; the S8V2 locks out after 7 tries and the American Standard A951X after 6.

What does E04 mean on a Trane or American Standard furnace?

An open limit. Most tables read "Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)". The S8V2 has no E04: it splits the same idea into E4.0 high limit, E4.1 reverse air-flow limit and E4.2 roll-out limit. A limit or roll-out switch that opens is a call for a qualified servicer.

Why does my Trane furnace display IdL, Ht1 or COF?

Those are status readings, not faults. Trane's S9 manual lists "IDL = Idle, no demand for cooling, heating, or fan", "HT1 = Demand for 1st stage gas heat" and "COF = Demand for continuous fan". An error shows as an E-code that alternates with the status and airflow readings.

My older Trane furnace flashes a red light three times. What does it mean?

On a furnace fitted with one of Trane's replacement controls, three red flashes are "PRESSURE SWITCH FAULT" in all three kit guides. A slow green flash is "NORMAL, NO CALL FOR HEAT" and a fast green flash "NORMAL, CALL FOR HEAT PRESENT". An original board may differ; check the label on the blower door.

Are American Standard furnace codes the same as Trane's?

Often, but not always. The replacement-control guides print one table for models whose prefix "May be "A" or "T"". The current American Standard A801X, A951X and A952V have their own manuals, and the A951X locks out after 6 failed ignitions where most Trane series stop at 3.

How do I reset a Trane furnace lockout?

E2.1 and E2.2 end in a one-hour lockout, and Trane's chart says the "Lockout period is for one hour." We found no homeowner reset procedure in these manuals. A code that returns after the lockout ends needs a qualified servicer.