Bryant and Payne Furnace Error Codes, by Model Family

Bryant / PayneBryant 830SA (Minor Series B&C); Payne PG96VAT (Series B all sizes, Series C sizes 60080, 60100, 66120); Payne PG96VTABRuns with warningCheck, then callLast updated:

Three documents, three different code schemes — check which one is yours before you read a table. This page covers exactly the Bryant and Payne furnace families whose code lists GridComfort can read from a manufacturer document: the Bryant 830SA (Minor Series B&C), the Payne PG96VAT (Series B all sizes; Series C sizes 60080, 60100 and 66120), and the Payne PG96VTAB. The 830SA and the PG96VAT both flash a two-digit code on an amber LED — first digit is the number of short flashes, second digit is the number of long flashes. The PG96VTAB does not: that generation has an on-board three-digit LCD and reports faults as a decimal code such as 10.1, so a two-digit table is the wrong table for it. Code numbering also differs between the two flash-code furnaces — the Payne publishes a code 33, the Bryant document publishes none. Nothing here is carried across from another brand or another model family.

Find your model family first

The model number is on the rating plate inside the furnace cabinet, and on Bryant units it is also decoded on the unit's own label. The first characters are what matter here.

Error codes, meanings, severity, and DIY rating
Model familyWhat it looks likeHow it reports a faultTable
Bryant 830SA, Minor Series B or CModel begins 830SA; the troubleshooting guide is titled "830SA (Minor Series B&C)"Amber LED, two-digit flash codeBryant 830SA codes
Payne PG96VATTwo-stage 4-way multipoise condensing furnace; Series B all sizes, Series C sizes 60080, 60100, 66120Amber LED behind the blower-door indicator, two-digit flash codePayne PG96VAT codes
Payne PG96VTABSame PG96 family, later control: three-digit LCD with menu/select and next/option buttons on the boardThree-digit LCD showing ##.#Payne PG96VTAB codes

If your Bryant or Payne is not one of these three, this page does not cover it. Bryant and Payne have each sold many furnace generations, the control boards changed with them, and a code number that means one thing on an 830SA can mean something else on a furnace built five years earlier. Rather than publishing a "Bryant furnace codes" list that would be wrong for most Bryant furnaces, GridComfort publishes only what the documents in the Sources section actually cover.

Bryant 830SA (Minor Series B&C) status codes

Every row below is transcribed from the Bryant 830SA (Minor Series B&C) Troubleshooting Guide, document GFULN80-B-01TS, pages 6 and 7, cross-checked against the individual code sections later in the same guide. Nothing is added from another Bryant furnace or another brand.

Before the table, three LED states that are not codes: continuous off means check for 115 V AC at L1 and L2 and 24 V AC at SEC-1 and SEC-2; continuous on means the control has 24 V AC power; rapid flashing means the 115 V AC line-voltage polarity is reversed. A code proper is two digits — short flashes give the first, long flashes give the second.

Error codes, meanings, severity, and DIY rating
CodeWhat the Bryant document says it meansReset behavior
11No previous codeStored codes are erased automatically after 72 hours
12Blower on after power up (115 V AC or 24 V AC)Blower runs 90 seconds if the unit is powered up during a call for heat, or if R-W opens during a blower on-delay
13Limit circuit lockout — a limit, draft safeguard, burner thermal switch or blocked vent switch is openControl auto-resets after three hours
14Ignition lockoutControl auto-resets after three hours; the document routes you to code 34
21Gas heating lockoutControl will not auto-reset
22Abnormal flame-proving signal — flame is proved while the gas valve is de-energizedInducer runs until the fault is cleared
23Pressure greater than 0.15-in. w.c. at start-up
24Secondary voltage fuse is open
25Invalid model selection or setup errorFour flashes on power-up means the control is defaulting to the model stored in memory
26Wiring harness — the yellow jumper in the main plug of the harness is damaged or missing
31Pressure transducer input does not sense target pressure, or pressure is out of range
34Ignition proving failureThe control tries ignition four times before lockout 14
42Inducer motor fault — no RPM pulses within 20 seconds of a heat request, inducer outside its valid range, or RPM signal lost for 5 seconds
45Control circuitry lockout — gas valve relay stuck open, flame sense circuit failure, or software check errorAuto-resets after one hour

There is no Bryant 830SA code 33. The document's code sequence runs 31 then 34. If you are counting flashes and arriving at 33 on an 830SA, count again — the first digit is short flashes and the second is long flashes, and it is easy to read a 3-and-4 as a 3-and-3.

Recalling stored codes on this furnace, per the same document: disconnect the "R" thermostat lead, reset power, and put setup switch SW1-1 in the ON position. To clear the history, put SW1-1 ON and jumper thermostat terminals R, W/W1 and Y/Y2 together until code 11 flashes. Both of those are inside the cabinet on a live board, which is why they are listed here as what the document says rather than as something to go and do.

Payne PG96VAT status codes

These rows come from the Payne PG96VAT Installation, Start-up, Operating and Service and Maintenance Instructions, catalog number IM-PG96VAT-13, whose troubleshooting guide runs across pages 87 and 88, with the status-code retrieval procedure on pages 75 and 76. This furnace is a two-stage unit, which is why several codes exist in low-heat and high-heat pairs that the Bryant list has no equivalent for.

This furnace shows its code at an indicator in the blower door. The amber LED is on continuously, rapid flashing, or flashing a two-digit code — first digit short flashes, second digit long flashes. The control stores the last seven codes and keeps them through a power interruption.

Error codes, meanings, severity, and DIY rating
CodeWhat the Payne document says it meansReset behavior
11No previous codeCodes erase after 72 hours, or manually with SW1-1 ON and R, W/W1 and Y/Y2 jumpered
12Blower on after power up (115 V or 24 V) — normal operationBlower runs 90 seconds
13Limit circuit lockout — the limit or flame rollout switch open longer than 3 minutes, or 10 successive limit trips during high-heatAuto-resets after 3 hours; the document points to code 33
14Ignition lockout — failed to ignite gas and prove flame in 4 attemptsAuto-resets after 3 hours; the document points to code 34
15Blower motor lockout — blower failed to reach 250 RPM, or failed to communicate within 30 seconds of turn-on, in two successive heating cyclesAuto-resets after 3 hours
21Gas heating lockoutTurn off power and wait 5 minutes to retry
22Abnormal flame-proving signal — flame proved while the gas valve is de-energizedInducer runs until the fault is cleared
23Pressure switch did not open
24Secondary voltage fuse is open
25Invalid model selection or setup errorFour flashes on power-up means model plug PL4 is missing and the control is using the model in memory
31High-heat pressure switch or relay did not close, or reopened
32Low-heat pressure switch did not close, or reopenedIf open longer than 5 minutes the inducer shuts off for 15 minutes before retrying
33Limit circuit fault — the limit or a flame rollout switch is open, or the furnace is in high-heat-only mode after 2 successive low-heat limit tripsIf open longer than 3 minutes the code becomes lockout 13. The flame rollout switch requires a manual reset
34Ignition proving failureThe control repeats the ignition sequence 3 more times before lockout 14
43Low-heat pressure switch open while the high-heat pressure switch is closed
45Control circuitry lockout — flame circuit failure, gas valve relay stuck open, or software check errorAuto-resets after 1 hour

Codes 41 and 42 are referenced inside this document but never defined in it, so they are not listed above. The complete list is printed on the service label on the blower door of your own furnace.

Payne PG96VTAB: a decimal code scheme

The PG96VTAB is documented in Payne's Installation, Start-up, Operating and Service and Maintenance Instructions, catalog number IM-PG96VTAB-01 Rev. A, and the control section runs from page 52 to page 60. It is worth reading that section before looking for a code, because this generation does not report faults the way the other two furnaces on this page do.

This generation replaced the flash-code LED with an on-board three-digit LCD and pushbutton navigation. On startup it alternates the Model Program Number (PRG) and the software version (uEr). In normal running it shows an operating mode rather than a fault: iDl idle or standby, Ht2 high heating, Ht1 low heating, CL2 high cooling, CL1 low cooling, Hpd heat pump defrost, Cfn / CF2 / CF3 continuous fan, bLr blower running as the secondary unit of a twinned pair. An active fault appears in the form ##.# — a two-digit code, a decimal point, and a subcode.

Error codes, meanings, severity, and DIY rating
CodeWhat the Payne document says it meansWhere it is stated
10.1115-V polarity is incorrect. The status LED flashes rapidly and the furnace will not operate"115-V Wiring" p. 25; "ELECTRICAL CONNECTIONS" p. 60; start-up check item 1, p. 55
24.1The 24-V circuit's 3-amp automotive-type fuse is blown and needs replacing — with a 3-amp fuse only"ELECTRICAL CONNECTIONS" p. 60
32.2Shown during the documented pressure-switch check, with the inducer motor leads disconnected, when the low pressure switch is working correctly"Check Pressure Switch(es)" p. 58

Those three are the only PG96VTAB decimal codes this page publishes, and that is a limitation of the document rather than of the furnace. The full decimal list on this model lives on the furnace's own service label (Fig. 59) and in the troubleshooting guide (Fig. 70); both are reproduced inside the PDF as label images with no readable text, and no other Payne document publishes them. Rather than guess that 13.1 is a variant of the older code 13, or copy a list from a repair forum, GridComfort leaves them out. Open the blower door and read the service label on your own unit — it is the authoritative list for your control.

Fault history on this control is read from the display rather than by flashing: press menu/select until FLt appears, then next/option to step through the last seven faults. Faults stay in memory for 72 hours of powered operation, and CLr clears them.

Where a Bryant or Payne code matches a Carrier code

Bryant, Payne and Carrier are related brands, and on the codes below the wording in the Bryant or Payne document matches the wording on the Carrier page for the same number. Where that is true, the longer Carrier explanation is worth reading. Where it is not true, there is no link, and the absence is the point.

Error codes, meanings, severity, and DIY rating
CodeBryant 830SAPayne PG96VATPayne PG96VTABCarrier detail page
13Limit circuit lockoutLimit circuit lockoutNot published in the manualCarrier 13
14Ignition lockoutIgnition lockoutNot published in the manualCarrier 14
33No code 33 in the Bryant documentLimit circuit faultNot published in the manualCarrier 33
34Ignition proving failureIgnition proving failureNot published in the manualCarrier 34

The Carrier pages describe the Carrier furnaces they were written against. They are linked here because the meaning of the number is the same in these documents, not because the furnaces are interchangeable — component locations, reset behavior and the rest of the code list all differ.

What a homeowner can actually do

Bryant's own troubleshooting guide draws this line in its safety section, and it is the same line on every furnace on this site: "Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel."

  1. Read the code without opening anything. On the 830SA and the PG96VAT there is an indicator visible at the blower door. Count short flashes, pause, count long flashes. That is your code.
  2. Check the thermostat and the filter. A dirty filter or a restricted duct system is named directly in the Bryant and Payne text for codes 13 and 33, and replacing a filter is the one job both manufacturers hand to the owner.
  3. Check that nothing is blocking the vent or the combustion-air intake outside. Restricted vent, excess wind and inadequate combustion air appear in the causes for 13, 31 and 32. Looking at a vent terminal from outside is not service work.
  4. Note whether the code is a lockout that resets itself. Bryant 13, 14 and Payne 13, 14, 15 auto-reset after three hours; Payne 21 needs a five-minute power-off; Bryant 21 does not auto-reset at all. A furnace that keeps re-locking out after an automatic reset is telling you the underlying fault is still there.
  5. Stop at the door. Everything past this — the setup switches, the code-recall procedures, the pressure transducer readings, the flame-sensor microamp checks — is done on a live board inside the cabinet, and both documents put it under a trained-service-personnel warning.

When to call a technician

  • Any code involving flame proving, the gas valve or a flame rollout switch: Bryant 21, 22, 34, 45; Payne 21, 22, 34, 45. A flame rollout switch is a manual-reset device that trips because combustion left the burner box.
  • A limit circuit lockout that returns after the automatic reset and a filter change.
  • Any pressure-switch or transducer code (Bryant 23, 31; Payne 23, 31, 32, 43) — diagnosis needs a manometer and the manufacturer's target pressures.
  • PG96VTAB code 10.1, which means the incoming 115 V polarity is wrong. That is a wiring fault at the furnace or upstream of it.
  • Anything you cannot match to a code in your own furnace's documentation.

Frequently asked questions

What does code 33 mean on a Bryant furnace?

The Bryant 830SA (Minor Series B&C) troubleshooting guide does not publish a code 33 at all — its list runs 31 then 34. On a Payne PG96VAT, code 33 is a limit circuit fault: the limit or a flame rollout switch is open, or the furnace has dropped into high-heat-only mode after two successive low-heat limit trips. If you are reading 33 on an 830SA, count the flashes again; the first digit is short flashes and the second is long flashes.

Are Bryant and Payne error codes the same as Carrier's?

For codes 13, 14, 33 and 34 in the three documents on this page, the printed meanings match the Carrier pages on this site, and each of those rows is linked. That is not a general rule. Code numbering, the presence of a code at all, and the reset behavior all vary by furnace family, and the Bryant document has no 33 while the Payne PG96VTAB uses an entirely different decimal scheme.

Why does my Payne show 10.1 instead of a two-digit code?

Because it is a PG96VTAB. That generation has an on-board three-digit LCD rather than a flash-code LED, and it reports faults as a decimal code in the form ##.#. Code 10.1 on that control means the incoming 115-V polarity is reversed and the furnace will not operate. A two-digit flash-code table is the wrong table for that furnace.

How do I read a two-digit flash code?

On the Bryant 830SA and the Payne PG96VAT the amber LED gives the first digit as short flashes and the second digit as long flashes. Three short flashes then four long flashes is code 34. Continuous on means the control simply has 24-V power, and rapid flashing on either furnace means the 115-V line-voltage polarity is reversed.

How long do stored codes last?

On both flash-code furnaces the control holds the codes for 72 hours and then erases them automatically. The Payne stores the last seven codes and keeps them through a power interruption. On the PG96VTAB the fault history is read from the display under FLt, holds seven faults, and also expires after 72 hours of powered operation.

My furnace locked out and then started again by itself. Is it fixed?

No. Several of these codes auto-reset by design — Bryant 13 and 14 after three hours, Payne 13, 14 and 15 after three hours, Bryant and Payne 45 after one hour. The control retrying is not the fault clearing. A furnace that keeps locking out and retrying is repeating the same failure on a timer, and the code it stored is what a technician needs.

The four Carrier code pages this hub links out to: Carrier 13, Carrier 14, Carrier 33 and Carrier 34. The section index for every furnace brand covered here is furnace error codes by brand.