Generac Next Generation Error Codes (Power Zone 200)

Generac Next GenerationNext Generation air-cooled home standby, 10–28 kW, Power Zone 200 controllerLast updated:

Generac's Next Generation home standby generators (10 to 28 kW) use the Power Zone 200 controller, and Generac says "Faults and Alarms now appear in Mobile Link & Field Pro instead of controller display." Below is every code on Generac's own Next Generation list, grouped by what it's about, with the message Mobile Link shows for it. That message is Generac's instruction for the code: a few tell you to check the battery or the oil level, and most say to contact a dealer.

Key facts

QuestionShort answerSource
Which generatorsNext Generation air-cooled home standby, 10, 14, 18, 22, 24, 26 and 28 kWGenerac
ControllerPower Zone 200 (Guardian series uses Evolution 2.0)Generac
Where the code showsMobile Link and Field Pro, not the controller displayGenerac
How to clearPress and hold the OFF button for three seconds, then attempt to start the generator in manual mode by pressing the MANUAL buttonGenerac
If the code returnsDealer service is requiredGenerac
What you can do yourselfFollow the Mobile Link message for your code. Generac says most codes exceed typical DIY troubleshooting.Generac

Is my generator a Next Generation unit?

Generac sells Next Generation air-cooled standby units in 10, 14, 18, 22, 24, 26 and 28 kW, and the prior Guardian series tops out at 26 kW. The quickest tell is the controller: Next Generation units use the Power Zone 200, while Guardian units use Evolution 2.0. Of the Power Zone 200, Generac says: "These controllers do not have a display. Error messages can only be viewed in the Mobile Link app." If you have a Guardian, the codes are on the main Generac code list.

How to clear a Next Gen alarm

Generac's clearing procedure for a Next Generation unit is short: press and hold the OFF button on the controller for three seconds, then attempt to start the generator in manual mode by pressing the MANUAL button. If the error code returns, Generac says dealer service is required. The steps as Generac words them:

  1. Go to the front of the generator, lift the lid, and locate the controller on the top right side of the generator.
  2. Press and hold the OFF button for three seconds.
  3. Attempt to start the generator in manual mode by pressing the MANUAL button.
  4. If the error code returns, dealer service is required.

Generac adds: "Note: If the generator starts successfully in manual mode, it will continue to run until shut down with the AUTO or OFF button."

With a Premium Mobile Link plan, Generac lists one more option: "Remote alarm dismissal (Premium): Clear certain non-critical alarms directly from Mobile Link."

Generac's own framing of the list is blunt: "Most error codes listed below exceed typical DIY troubleshooting and may require a Generac Independent Authorized Service Dealer (IASD)." Its general code article adds that "Many yellow light error codes can be addressed by the end user/consumer". The status light tells you which kind you have: "Alarm codes will display a red indicator LED light. Warnings and maintenance reminders will display a yellow indicator LED light."

Full list of Next Generation codes

The four columns are Generac's own: the code, the alarm name Generac displays, whether it is an alarm or a warning, and the message Mobile Link shows, all in Generac's wording. A range such as 4900–4917 is a single row on Generac's list. A dash means Generac's list gives no Mobile Link message for that code. Where we have a page on the same code, it's linked; a link marked "(Guardian / Evolution page)" goes to a page written for Guardian controllers that doesn't state it covers Next Generation units.

Start, speed and engine protection

Generac Next Generation codes, start, speed and engine protection: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
1100 (Guardian / Evolution page)OvercrankALARMThe generator has experienced an overcrank alarm. Please contact a dealer.
1200–1208OverspeedALARMThe generator has experienced an overspeed alarm. Please contact a dealer.
1522RPM SensorALARMThe generator has experienced a no crank RPM Sensor alarm. Please contact a dealer.
1600UnderspeedALARMThe generator has experienced an underspeed alarm. Please contact a dealer.
5100–5117Engine SpeedALARM/WARNINGThe generator has experienced an engine speed alarm. Please contact a dealer.
The generator has experienced an engine speed warning. Please contact a dealer.
5200–5217Cylinder Head Temperature 1ALARM/WARNINGThe generator has experienced a cylinder head temperature alarm. Please contact a dealer.
The generator has experienced a cylinder head temperature warning. Please contact a dealer.

Oil

Generac Next Generation codes, oil: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
2126Low Oil LevelWARNING—
3301–3304Engine Oil PressureALARMThe generator has experienced an engine low oil pressure alarm. Please contact a dealer.
The generator has experienced an engine oil pressure alarm. Please contact a dealer.
5415–5417Engine Oil LevelWARNINGThe generator has a high oil level warning. Remove loads, let generator cool, check oil level and drain oil if necessary before resetarting. If alarm reappears, please contact a dealer.
The generator has a low oil level warning. Remove loads, let generator cool, check oil level and add oil if necessary before restarting. If alarm reappears, please contact a dealer.

Oil type and capacity by model are on our Generac oil page.

Output voltage and load

Generac Next Generation codes, output voltage and load: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
1800–1801OvervoltageALARMThe generator has experienced an overvoltage alarm. Please contact a dealer.
1900–1907UndervoltageALARMThe generator has experienced an undervoltage alarm. Please contact a dealer.
2100Overload Remove LoadALARMThe generator has experienced an overload alarm. Please contact a dealer.
2115AVR PWM OverloadALARMThe generator has experienced an AVR PWM alarm. Please contact a dealer.
2116Generator kW Overload (3-phase nodes only)ALARM—
2117Phase kW Overload (3-phase nodes only)ALARM—
7000Overload CooldownWARNINGThe generator has experienced an overload and is in cool down mode. If condition persists, contact a dealer.

Battery and charger

Generac Next Generation codes, battery and charger: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
2750Low BatteryWARNINGThe battery charge level has fallen below the acceptable level. Please inspect or replace the battery. If necessary, please contact a dealer.
2751Very Low BatteryALARMThe battery charge level has fallen below the acceptable level. Please inspect or replace the battery. If necessary, please contact a dealer.
2760Battery ProblemWARNINGThe battery is not charging properly. Please replace the battery or contact a dealer.
2770Charger WarningWARNINGThe battery is not charging properly. Please replace the battery or contact a dealer.
2780Charger Missing ACWARNINGThe unit is not charging the battery properly. Please contact a dealer.
3803–3817Battery Potential / Power Input 1ALARM/WARNINGThe generator has experienced a battery voltage alarm. Please contact a dealer.
The generator has experienced a battery voltage warning. Please contact a dealer.

For battery specs and the Next Generation replacement steps, see Generac battery replacement.

Wiring and transfer switch

Generac Next Generation codes, wiring and transfer switch: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
2094–2099Wiring ErrorALARMThe generator sensing-wire connections to a remote emergency shutdown switch have been miswired. Please contact a dealer.
The generator sensing-wire connections to the transfer switch have been miswired. Please contact a dealer.

Engine sensors and fuel system

Generac Next Generation codes, engine sensors and fuel system: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
3000ECU FaultedALARMThe generator has experienced an engine alarm. Please contact a dealer.
3100–3117Engine Throttle Valve 1 Position 1ALARM/WARNINGThe generator has experienced an engine alarm. Please contact a dealer.
The generator has experienced an engine warning. Please contact a dealer.
3200–3217Engine Fuel Delivery PressureALARM/WARNINGThe generator has experienced an engine high fuel pressure alarm. Please contact a dealer.
The generator has experienced an engine low fuel pressure alarm. Please contact a dealer.
The generator has experienced an engine fuel pressure alarm. Please contact a dealer.
The generator has experienced an engine high fuel pressure warning. Please contact a dealer.
The generator has experienced an engine low fuel pressure warning. Please contact a dealer.
3400–3417Engine Intake Manifold #1 PressureALARM/WARNINGThe generator has experienced a high intake manifold pressure alarm. Please contact a dealer.
The generator has experienced a low intake manifold pressure alarm. Please contact a dealer.
The generator has experienced an intake manifold pressure alarm. Please contact a dealer.
The generator has experienced a high intake manifold pressure warning. Please contact a dealer.
The generator has experienced a low intake manifold pressure warning. Please contact a dealer.
3500–3517Engine Intake Manifold 1 TemperatureALARM/WARNINGThe generator has experienced a low intake manifold temperature alarm. Please contact a dealer.
The generator has experienced a low intake manifold temperature warning. Please contact a dealer.
4101Engine Position SensorALARMThe generator has experienced an engine primary sync loss. Please contact a dealer.
4201Engine Timing SensorALARMThe generator has experienced an engine secondary sync loss. Please contact a dealer.
4300–4317O2 SensorALARM/WARNINGThe generator has experienced an O2 sensor alarm. Please contact a dealer.
The generator has experienced an O2 sensor warning. Please contact a dealer.
4503–4507Engine Ignition Coil #1ALARMThe generator has experienced an engine ignition coil alarm. Please contact a dealer.
4603–4607Engine Ignition Coil #2ALARMThe generator has experienced an engine ignition coil alarm. Please contact a dealer.
4900–4917Engine Fuel Valve 1 PositionALARM/WARNINGThe generator has experienced an engine fuel valve alarm. Please contact a dealer.
The generator has experienced an engine fuel valve warning. Please contact a dealer.
5303–5304Engine Fuel Shutoff 2 ControlALARMThe generator has experienced an engine fuel shutoff control alarm. Please contact a dealer.

Controller, configuration and communication

Generac Next Generation codes, controller, configuration and communication: displayed alarm, alarm or warning, and the Mobile Link message, in Generac's wording
E-codeDisplayed AlarmAlarm/WarningMessage in Mobile Link
502Missing Config - Parameter GroupALARMA critical configuration parameter has not been set. Please contact a dealer.
504Missing Config - Fuel TypeALARMA critical configuration parameter has not been set. Please contact a dealer.
505Invalid Serial NumberALARMA critical configuration parameter has not been set. Please contact a dealer.
1000–1006Controller FaultALARMThe generator has experienced an internal alarm on the controller. Please contact a dealer.
2070Keypad MissingALARMThe controller board is not recognizing the keypad. Please contact a dealer.
2075Quadclops MissingWARNINGThe generator does not recognize the external LED lights connection. Please contact a dealer.
2090Model ID Sync FailedWARNINGA model configuration setting has failed to sync with controller.
2095Fuel Type Sync FailedWARNINGA model configuration setting has failed to sync with controller.
2120Serial Num Sync FailedWARNINGA model configuration setting has failed to sync with controller.
2125Run Hours Sync FailedWARNINGA model configuration setting has failed to sync with controller.
2670CANBus ErrorALARMThe generator has experienced a CANBus alarm. Please contact a dealer.
2790SEEPROM AbuseWARNINGThe generator has experienced an internal warning on the controller. Please contact a dealer.

A code that isn't on this list

If the number in Mobile Link isn't in the tables above, it isn't on Generac's published Next Generation list; 2650, 2900, 2904, 3519 and 4800, for example, don't appear on it. Generac's general code article suggests: "If you don't see your specific code, try referencing an article about a code with the first two digits of the code you're seeing." Write down the exact number and the message Mobile Link shows, and give both to a Generac dealer. Guardian-series codes are on the main Generac list.

When to call a dealer

  • The code returns after you hold OFF for three seconds and press MANUAL. Generac: "If the error code returns, dealer service is required".
  • The Mobile Link message says so. Most messages on Generac's list end with "Please contact a dealer."
  • An oil level warning (5415–5417) comes back. Generac's message has you remove loads, let the generator cool and check the oil level first, then: "If alarm reappears, please contact a dealer."

Generac's Dealer Locator Tool finds a Generac Independent Authorized Service Dealer (IASD).

Not sure the generator can carry the load?Generator Wattage Calculator Running watts, the largest starting surge, and a generator class from manufacturer charts.

Frequently asked questions

Why doesn't my Next Gen controller show the code?

Generac says "Faults and Alarms now appear in Mobile Link & Field Pro instead of controller display," and that Power Zone 200 controllers "do not have a display."

How do I reset a Generac Next Gen error code?

Press and hold the OFF button for three seconds, then attempt to start the generator in manual mode by pressing the MANUAL button. If the error code returns, Generac says dealer service is required.

What does code 4904 mean on a Generac Next Gen?

It falls in Generac's 4900–4917 row, "Engine Fuel Valve 1 Position", listed as ALARM/WARNING. The Mobile Link messages for that row are "The generator has experienced an engine fuel valve alarm. Please contact a dealer." and "The generator has experienced an engine fuel valve warning. Please contact a dealer."

What does code 5417 mean?

It's in the 5415–5417 row, "Engine Oil Level", a WARNING. Generac gives two Mobile Link messages for that row: "The generator has a high oil level warning. Remove loads, let generator cool, check oil level and drain oil if necessary before resetarting. If alarm reappears, please contact a dealer." and "The generator has a low oil level warning. Remove loads, let generator cool, check oil level and add oil if necessary before restarting. If alarm reappears, please contact a dealer."

What does code 2125 mean?

"Run Hours Sync Failed", a WARNING. The Mobile Link message: "A model configuration setting has failed to sync with controller."

What does code 2760 mean?

"Battery Problem", a WARNING. The Mobile Link message: "The battery is not charging properly. Please replace the battery or contact a dealer." See code 2780 for how the battery and charger codes 2750, 2760, 2770 and 2780 differ.