Generac Portable Generator Fault Codes and Warning Lights

GeneracGenerac portable generators: GP6500, GP6500E and GP8000E (COsense lights); GP15500EFI and GP18000EFI (EFI blink codes)Unit will not runCheck, then callLast updated:

Generac's portable generators report problems differently from its home standby units. Depending on the model, a problem shows up in one of three ways: a COsense badge that blinks red or yellow after an automatic shut-off; a Malfunction Indicator Lamp (MIL) on the GP15500EFI and GP18000EFI that flashes a two-digit code such as 6-1; or an engine that starts and shuts off right away, which Generac's troubleshooting guide traces to low oil level or a COsense shut-off. Find your model below, read the light, and follow Generac's correction.

Key facts
SymptomGenerac Portable Generator Fault Codes and Warning Lights
Applies toGenerac portable generators: GP6500, GP6500E and GP8000E (COsense lights); GP15500EFI and GP18000EFI (EFI blink codes)
SeverityUnit will not run
DIYCheck, then call — owner-level checks first, then a dealer
Last checked

Carbon monoxide: if the COsense light is blinking red, the generator shut itself off because carbon monoxide was accumulating. Generac's manual says to move the generator to an open, outdoor area and point the exhaust away from people and occupied buildings before restarting it.

Key facts

Key facts about Generac portable generator warning lights and fault codes, with the source for each
QuestionShort answerSource
Blinking red COsense lightThe generator was shut off due to an accumulating CO hazardGenerac GP6500 / GP6500E / GP8000E manual
Blinking yellow COsense lightA COsense system fault; COsense no longer provides protection and the generator shut offGenerac GP6500 / GP6500E / GP8000E manual
How long the light blinksAt least five minutesGenerac GP6500 / GP6500E / GP8000E manual
EFI blink codes (GP15500EFI, GP18000EFI)Long flashes of 1.2 seconds, then short flashes of 0.25 second; 6 long + 1 short = code 6-1Generac EFI manual and support article
Starts, then shuts off right awayLow oil level, or a COsense shut-off (red or yellow light)Generac troubleshooting guide
Who to callA Generac Independent Authorized Service Dealer (IASD)Generac

COsense red and yellow lights (GP6500, GP6500E, GP8000E)

COsense models have a COsense badge on the side of the generator. The GP6500 / GP6500E / GP8000E owner's manual describes both lights, and its troubleshooting table gives the cause and the correction for each one, in these words:

COsense lights: cause and correction from the GP6500 / GP6500E / GP8000E manual's troubleshooting table, in Generac's wording
LightCauseCorrection
Blinking REDCOsense shut-off due to accumulating carbon monoxide if a red light blinks on the side panel badge.Follow all safety instructions and relocate generator to an open area outside, far away from windows, doors and vents.
Blinking YELLOWCOsense shut-off due to a system fault if a yellow light blinks on the side panel badge.Start to confirm yellow light blinks when/if generator shuts-off. If COsense continues to fault and shut-off, contact IASD.

Red. The manual: "After a shut-off, a blinking RED light in the COsense badge on the side of the generator provides notification that the generator was shut off due to an accumulating CO hazard. The RED light will blink for at least five minutes after a CO shut-off. Move the generator to an open, outdoor area and point the exhaust away from people and occupied buildings. Once relocated to a safe area, the generator can be restarted and the proper electrical connections made to supply electrical power." It adds: "Introduce fresh air and ventilate the location where the generator had shut down."

Yellow. The manual: "If a COsense system fault has occurred and no longer provides protection, the portable generator is shut off automatically and the YELLOW light will blink for at least five minutes in the COsense badge to notify the user of the fault. The COsense module can only be diagnosed and repaired by a trained technician at the dealer. The generator can be re-started, but may continue to shut-off."

COsense also reacts to carbon monoxide from other fuel-burning sources nearby, such as another generator's exhaust pointed at it; the manual says such a shut-off "is not an error." It also says: "COsense is not a substitute for an indoor carbon monoxide alarm." Generac's general portable troubleshooting guide gives the same two corrections, in slightly different words, for units equipped with COsense, and the 15.5 / 18.0 kW EFI manual carries the same COsense description for units so equipped.

Generac's fault-code article applies to the GP15500EFI and GP18000EFI, and the matching owner's manual (rated 15.5 / 18.0 kW) carries the same table. The Malfunction Indicator Lamp on the control panel "displays a 2-digit code by flashing a sequence of long and short flashes. Long flashes are 1.2 seconds, and short flashes are 0.25 second." Generac's example: "Fault code 6-1 is displayed by: 6 long blinks = 6, one second pause, 1 short blink = 1."

Timing diagram of Generac EFI fault code 6-1: six long flashes of 1.2 seconds, a one-second pause, then one short flash of 0.25 second
Flash lengths and the one-second pause are from Generac's EFI manual and support article and are drawn to scale; Generac doesn't give the gap between individual flashes, so those gaps are not to scale.

How the lamp behaves, per the manual:

  • When the key is switched ON, the MIL lights for 0.5 second; that does not indicate a fault.
  • With more than one fault, the MIL pauses two seconds between codes, then pauses five seconds and repeats the list.
  • A shutdown fault stops the engine (or keeps it from starting). "Before the unit can be started, the key must be first turned to the OFF position to clear the active fault."
  • The engine control module keeps faults for three ON-OFF key cycles. To see them, turn the key ON without starting the engine; after 30 seconds the MIL flashes the stored faults.
Generac EFI fault codes from the 15.5 / 18.0 kW owner's manual: fault code, cause, condition and correction, in Generac's wording
Fault CodeCauseConditionCorrection
1-1CO Monitor1. Carbon Monoxide above limit.
2. Input voltage to module below normal range.
1. Move generator outside.
2. Contact IASD.
1-2Battery Voltage1. Battery voltage above normal operating range.1. Contact IASD.
1-3Battery Voltage1. Battery voltage below normal operating range.1. Charge battery to correct level.
5-2Engine Speed1. No or low fuel.
2. Engine speed below normal operating range.
1. Fill fuel tank.
2. Contact IASD.
6-1Engine Oil Pressure1. Low oil pressure.
2. Switch voltage not detected.
1. Fill crankcase to correct level.
2. Contact IASD.
OtherMultiple1. Multiple1. Contact IASD.

The manual's note under the table: "Contact an IASD for full list of fault codes." Generac's support article prints the same codes and says its table "provides common fault codes and is for informational purposes only." It words the first 1-1 correction differently: "Never run a generator indoors or in a partially enclosed area. Move the generator."

Engine starts, then shuts off right away

Generac's portable troubleshooting guide lists three issues under "Engine starts and shuts off right away": low oil level, a COsense shut-off with a red light, and a COsense shut-off with a yellow light. For low oil level its solution is "Fill the crankcase to the correct level." The GP6500 / GP6500E / GP8000E manual explains the shutdown: "The engine is equipped with a low oil level sensor to shut down the engine automatically when the oil level drops below a specified level. The engine will not run until the oil has been filled to the proper level." That manual's own troubleshooting table lists low oil level under "Engine will not start; or starts and runs rough" and "Engine shuts down during operation", and its "Engine starts and shuts off right away" row lists only the two COsense shut-offs. For oil type and capacity by model, see our generator oil guide.

No code, but something's wrong

Generac's quick reference guide covers portables with no fault code at all. It applies to most portable generators, and features marked "(if equipped)" vary by unit. These are its full rows for four common problems, in Generac's words:

Generac's portable troubleshooting quick reference: problem, issue and solution, in Generac's wording
ProblemIssueSolution
Engine is running, but AC output is not availableCircuit Breaker is OPENReset Circuit Breaker
Engine is running, but AC output is not availablePoor connection or defective cord setCheck and repair
Engine is running, but AC output is not availableThe connected device is bad.Connect another device that is in good condition.
Engine is running, but AC output is not availableGFCI receptacle is OPEN (if equipped)Correct ground fault and press the reset button on GFCI
Engine is running, but AC output is not availableFault in the generatorContact IASD
Engine runs well at no-load, but bogs when load is appliedShort circuit in a connected loadDisconnect shorted electrical load.
Engine runs well at no-load, but bogs when load is appliedGenerator is overloadedReduce load - See the owner's manual for generator limits.
Engine runs well at no-load, but bogs when load is appliedThe engine speed is too slow.Contact IASD
Engine runs well at no-load, but bogs when load is appliedShorted generator circuitContact IASD
Engine runs well at no-load, but bogs when load is appliedClogged carburetorClean carburetor
Engine runs well at no-load, but bogs when load is appliedStale or old fuelReplace with fresh fuel.
Engine runs well at no-load, but bogs when load is appliedClogged spark arrestorClean spark arrestor screen
Engine will not start or starts and runs roughFuel shut-off is OFF.Turn the fuel shut-off ON.
Engine will not start or starts and runs roughDirty air filterClean or replace air filter(s)
Engine will not start or starts and runs roughOut of fuelFill fuel tank
Engine will not start or starts and runs roughStale fuelDrain the fuel tank and fill it with fresh fuel.
Engine will not start or starts and runs roughThe spark plug wire is not connected to the spark plug wireConnect wire to spark plug
Engine will not start or starts and runs roughWater in fuelDrain the fuel tank and fill it with fresh fuel.
Engine will not start or starts and runs roughOver chokingSet choke to no choke position.
Engine will not start or starts and runs roughLow oil LevelFill the crankcase to the correct level
Engine will not start or starts and runs roughBad spark plugReplace spark plug
Engine will not start or starts and runs roughClogged carburetorClean carburetor
Engine will not start or starts and runs roughExcessive rich fuel mixtureContact IASD
Engine will not start or starts and runs roughIntake valve stuck open or closed.Contact IASD
Engine will not start or starts and runs roughEngine lost compressionContact IASD
Pull cord keeps pulling loose , does not start the generator, and requires manually coilingThe recoil spring is damagedContact a local IASD.

Not sure the load fits? Use our generator wattage calculator. Owner's manuals for these models: Generac manuals by model.

When to call a dealer

  • The yellow COsense light keeps coming back. Generac's manual: "If COsense continues to fault and shut-off, contact IASD." The COsense module "can only be diagnosed and repaired by a trained technician at the dealer."
  • Your EFI code's correction is "Contact IASD": 1-2, the second condition of 1-1, 5-2 and 6-1, and "Other".
  • A troubleshooting row ends in "Contact IASD", such as "Fault in the generator" or "Engine lost compression".
Not sure the generator can carry the load?Generator Wattage Calculator Running watts, the largest starting surge, and a generator class from manufacturer charts.

Frequently asked questions

Why does my Generac GP6500 keep shutting off with a red light?

A blinking red COsense light means the generator "was shut off due to an accumulating CO hazard." Generac's manual says to move the generator to an open, outdoor area and point the exhaust away from people and occupied buildings; once it's relocated to a safe area, it can be restarted.

What does a blinking yellow light mean on a Generac portable?

On COsense models it means a COsense system fault: COsense "no longer provides protection," and the generator shut itself off. The manual says the generator "can be re-started, but may continue to shut-off," and if COsense continues to fault and shut off, to contact an IASD.

What is code 6-1 on a Generac GP18000EFI?

Engine Oil Pressure. Generac's table gives two conditions, "Low oil pressure." and "Switch voltage not detected.", with the corrections "Fill crankcase to correct level." and "Contact IASD."

How do I read a Generac EFI blink code?

Count the long flashes (1.2 seconds each), then, after the pause, the short flashes (0.25 second each). Generac's example: 6 long blinks, a one-second pause, then 1 short blink is code 6-1.

Are these the same as the Generac standby codes?

No. Generac's home standby generators use their own numeric code lists: see the Guardian / Evolution list or the Next Generation list.